Tps is the australian and new zealand authorised processing agent for pilkington fire resistant glazing and the australian distribution agent for the swiss made forster profile systems used for steel doors windows and curtain walls and the australian agent for fire curtains ltd.
Smoke resistant glass doors.
The doors shall have head and jamb stops astragals or rabbets at meeting edges and automatic closing devices.
Approval for single and double leaf door elements.
Positive latching devices are not required.
Smoke resistant to c5 specification.
Pairs of doors up to 2630 wide x 2630 high.
Door sizes up to max.
Special glazing and door solutions with fire resistant characteristics are not only made of fire resistant glass but are part of holistic tried and tested life safety systems.
From january 2021 the european standard en 1634 3 will be updated.
Smoke protection din en 13501 2 burglar resistance din v env 1627 to 1630 wk 2 door panels.
Windows shall be sealed to resist the free passage of smoke or be automatic closing upon detection of smoke.
Single doors up to 1315 wide x 2630 high.
For the selection of products manufactured developed and offered by coolfire we have kept in mind the recommendations of architects operators and end users.
Double doors single doors fixed lights screens see below.
Our fire rated glazing systems are ideal for all types of buildings including offices shopping centres residential apartments warehouses hospitals and.
Smoke control s visioneering range of fire rated glass systems such as fire windows glazed partition fire rated glazed doors fire resistant glass offer designers unrivaled flexibility.
We offer a special range of these fire system solutions to provide protection in escape routes and compartmentalize fire to limit the harmful effects of fire and smoke.
According to this standard the smoke proof capacity of the doors is tested separately.
1400 x 2500 mm security.
The european requirements regarding the smoke resistance of doors have recently been changed.
In the event of a fire emergency escape routes and information signs have to continue to be easily visible despite the smoke.
Fire resistive glazing provides protection from smoke flames and radiant and conductive heat transfer.
They are used for applications that require a fire rating that meets 250 f temperature rise criteria to limit the amount of heat transfer to the other side of the door or wall to the other.
Inward opening smoke doors outward opening smoke doors single and double leaf smoke doors with skylight side panel dimensions weights.
Tps technical protection systems.
Doors in smoke partitions shall comply with this section.
As a result the rules for smoke resistance will be more specific.